Summary of Qualifications
Mr K. has over 20 years of engineering experience pertaining to the operations, maintenance, and repair of Diesel Engines Steam Boilers/Turbines, and Gas Turbines. He has proven detail-oriented experience which has resulted in completion of high-priority maintenance jobs and compliance tasks ahead of fast-paced schedules with a positive outcome. Mr. K’s present duties enable him to apply his technical knowledge, expertise, experience, and organizational skills in a variety of physical locations and power generation technologies.
Chief Engineer (1992 to 2012), Horizon Lines, LLC, Oakland, California. ISO-9000 company:
- Performed vessel operation/maintenance, repair and overhaul on main and auxiliary steam boilers/turbines, diesel engines, and associated engine and deck equipment (including cargo systems).
- Prepared specifications for shipyard and major repair activities, and generating reports after major repairs, dry dockings and equipment surveys.
- Researched, specified, purchased and coordinated delivery of vessel equipment, supplies, parts and services.
- Implemented procedures, maintenance of documentation in compliance with the regulatory and statutory requirements of USCG, ABS, flag state, port state, classification society, International Maritime Organization (including International Safety Management system).
- Managed annual operation budget of $1.7 million and $11 million fuel purchases.
- Developed preventive maintenance schedules and procedures for equipment including semi-annual overhaul. Maintain and ensure the quality control of the ship’s Preventive Maintenance System (NS5).
- Trained personnel in all phases of vessel operations, maintenance, repair and safety (SMS).
- Extensive experience at-sea aboard Container ships, Tankers, Bulk Carries, Ferries, and Research vessels.
- Experienced managing Union labor and negotiating contracts and working with nonunion.
Representative Experience
NAES Senior Operations Analyst (Jan 7, 2012 to Current).
- Developed operating and maintenance procedures, training curriculum and preventive maintenance plans.
- Completed detailed operating instructions and systems descriptions for electric generating power plants
- Interfaced with clients on multiple levels (Project Management, Corporate, Plant Management, plant staff)
- (For additional information refer to page 2: Power Plants O&M services)
- Drawing from vast experience as Marine Chief Engineer, fill in as interim manager as needed. (see below)
NAES Maintenance Manager, MIT (MA Institute of technology) CUP (Central Utility Plant).
- Oversaw maintenance and repair of plant facilities and equipment of 20MW Siemens CGT, 33,000 Ton Capacity Steam/Elec. Chillers and 6 steam boilers. (Interim position: April to August 2013)
- Managed implementation of Maintenance Program and identified items needing improvement
- Worked with plant operating staff to assure plant facilities and equipment were maintained in a safe and efficient operating condition at all times.
- Implemented preventive and predictive maintenance program, including equipment failure records and trends. Performed root cause analysis (RCA) & corrective action report (CAR) as needed.
- Provided task lists and schedules for plant maintenance personnel and contractor for normal operating periods, planned outage periods, and forced outage situations.
- Maintained the plant's Maintenance Manuals, kept vendor maintenance and repairs filed and up to date
- Oversaw the issuance of purchase requisitions and purchase orders and inventory control.
- Responsible for following all procedures for Procurement and monthly/annual inventory reporting
- Assisted with hiring of maintenance personnel, sustained morale, and handled employee grievances
Education & Certification
- Calhoon MEBA Engineering School,
- Baltimore MD – 4 yr.
- Chief Engineer Steam/Diesel/Gas Turbine Unlimited HP– WV #466475, STCW98. Etc.
- Extensive list of industrial courses and seminars available upon request.
Software Proficiency
- Microsoft Office: Word, Excel, Power Point, Visio, and used Project Manager and CAD
- Computer Management Maintenance Systems: ABS NS5, Maximo, and Amos-D. Used: SAP and
- MP2.
- Extensive list of talents available on request and able to demonstrated knowledge of marine electrical and electronic systems.
Physical Condition: Excellent: Exercise regularly, Very active, Height weight proportionate @ 6’2”.
Power Plants O&M ser...